Hamyar Energy

Design of construction and industrial fire alarm and extinguishing systems

طراحی سیستم های اعلام و اطفاء حریق ساختمانی و صنعتی

Design of construction and industrial fire alarm and extinguishing systems

Design of water and foam fire extinguishing systems: The importance of having a water and foam fire extinguishing system is determined when the materials that can be extinguished only with this fire extinguishing system have caught fire and become rampant, increasing the flame and spreading to other parts. It is at this time that the proper prediction and design of such a system can extinguish the fire automatically or manually in the first moments of the fire and prevent the spread of the fire. Therefore, the design of the water and foam system for materials such as petroleum materials and flammable liquids is mandatory, because the cost of its implementation is much lower than when a fire accident occurs in that department.

Engineers and experts of Hamiar Energy Company have had the honor of serving in this sector for various factories such as paint and chemical production, petrochemical and refinery industries, and design fire extinguishing systems with water and foam using the most up-to-date methods.

This system consists of three parts: thick foam, water, and air. Correct and optimal design in this section helps to form a suitable mixture of these three elements and the final material, such as a homogeneous foam blanket, contains the flame and with factors such as cooling, separating the flame source from the surface of the product and vapors, and extinguishing the fire. fire

Hamiyar Energy Company guides employers and contractors in defining and designing the appropriate system for various projects according to their type of use. Consulting in the field of providing suitable solutions to advance the design projects of this system in accordance with international standards such as NFPA 16 is in the services of Hamyar Energy Company in this sector.

Our services in the design of construction and industrial fire alarm and extinguishing systems:

  • Project review based on NFPA 16 standard
  • Determining the use of different types of foam
  • Definition of foam fire extinguishing systems project
  • Examining and introducing the main components of the foam system, including how each component works, limitations, advantages and disadvantages
  • Introducing the system requirements based on the relevant standards based on different editions of the standard
  • Providing foam system P&ID
  • Foam extinguishing system design
  • Providing the class of piping used in foam fire extinguishing systems
  • Providing a program on how to inspect foam system items and its important components
  • Providing tips and how to implement the foam system and its important components
  • Tips for testing the foam system and its components
  • Providing tips on how to maintain and maintain the foam fire extinguishing system according to the standard

Design of construction and industrial fire alarm and extinguishing systems

Designing F&G fire alarm systems:

Sensitive industries such as refineries, petrochemicals, power plants, oil and chemical terminals and warehouses, pressure reduction stations, etc. are among the industries that can work with flammable liquids and gases. Therefore, the possible risks of working with these materials are also higher, and it requires the presence of fire and gas detector systems such as the F&G system. F&G systems are very advanced and accurate and have special and advanced capabilities. Connecting various gas and flame detectors to this system is one of its capabilities.

Having technical knowledge in this field, Hamiar Energy Company is able to design and implement this system in different and sensitive sectors of various industries. Other services of this company in this section are as follows:

  • Determination of danger zones
  • Checking and determining the correct classification of gases
  • Determining the types of gas detectors required
  • Determining the types of flame detectors required
  • Determining other fire alarm equipment required in F&G systems, such as LHDs, types of smoke and heat detectors, etc.
  • Investigating pollution and poisoning of electrochemical detectors
  • Investigation of mechanical damage
  • Investigating the need to use detectors with infrared technology
  • Investigating the need to use IR sensors for the long Open Path route.
  • Determining and deploying portable detectors
  • The possibility of using F&G systems based on PLC
  • Necessary training on how to test detectors and F&G system
  • Teaching various methods of calibration of gas detectors in different brands
  • F&G monitoring systems training
  • F&G system standard delivery
  • F&G systems maintenance training

Design of construction and industrial fire alarm and extinguishing systems

 

 

دیدگاه خود را با ما در میان بگذارید

AVG ratings 5 از 5
Vote count: 1 Vote

همیار انرژی در شبکه های اجتماعی

0912-8932367

مقالات بیشتر

Leave a Comment

Your email address will not be published. Required fields are marked *

دانلود محتوا

لطفا برای دریافت لینک دانلود اطلاعات خواسته شده را وارد نمایید
Scroll to Top
تماس با همیار انرژی

021-43000049