Extinguishing the fire of sensitive centers

“Fire extinguishing of sensitive centers, various solutions”

Extinguishing the fire of sensitive centers such as server rooms, museums, data centers, UPS (battery bank rooms) and such centers where there is a possibility of fire and its spread at any moment requires a system suitable for the use of that place. Therefore, in this article, we discuss the types, differences and applications of each of the systems.

Question :

In today’s world, information is the most valuable capital of an organization, so preserving and protecting this information is one of the basic principles of organizations, companies and public and private bodies. One of the dangers that have always threatened information is the lack of safe conditions in the storage of this information. The storage place of this information is centers such as servers, server racks, (Data centers, Server rooms) and various databases in the world, all of which are preserved and protected in high-value devices. These devices and equipment are maintained and processed by devices that are all connected to a power source such as electricity. Connecting each device to a power source causes heat in electrical equipment. The heat generated at any moment increases the possibility of fire in the place where this information is stored. The occurrence of any kind of fire accident and the loss of the mentioned valuable information in a fraction of a minute. The implementation of the fire extinguishing system in the place of storage of this information is very high, so the mentioned issue and the need to prevent this issue is necessary and necessary.

solution :

To prevent the aforementioned problem or to prevent the mentioned problem, you must think of a solution. In the world of safety and firefighting equipment, automatic fire alarm and extinguishing systems that have been invented and designed with different methods, these systems can be water automatic fire extinguishing systems, powder automatic fire extinguishing systems, gas automatic fire extinguishing systems or He mentioned the combined automatic fire extinguishing systems. Therefore, each of these systems has different applications and conditions for use, but here the main issue is the use of the desired places for storing this information, which are all considered as part of the category of sensitive places. Therefore, for places with special use or devices and equipment and sensitive devices of airplanes, trains, ships, cars, hotels, banks, refineries, military industries, libraries, document centers, oil and gas extraction stations. and sensitive switchboards, the use of gas fire extinguishing systems is suggested and required.

Types of automatic fire extinguishing systems commonly used in the world are the use of halon gases (clean agent) and various gases such as FM200, CO2 (carbon dioxide), IG55, Novec, Aerosol.

Action:

To implement the solutions presented for the problem raised in this article, it is necessary to act from the design of automatic fire alarm and extinguishing systems to the implementation of these systems based on international and domestic standards. Followed standards such as NFPA2010, NFPA12, ISIRI18755. The design of automatic warning and extinguishing systems in a general and standard way or according to the use of the desired brand in these systems, special software such as VDS software can be used. In the design of gas fire extinguishing systems, there should be points such as safety factors, the presence or absence of humans or living users in the intended location, evacuation time, the duration of the possibility of human presence in the environment after the evacuation of fire extinguishing gas at the location. The initial costs for purchase and implementation were carefully considered. It is also important to what consultant or company you give the design and implementation of your automatic gas fire extinguishing system to. Usually, in Iran, you should choose consultants who have experience in this field and are approved by the Tehran Fire Department, which is Hamyar Energy.

Fire notifications for these places are considered based on the number of desired zones, the area covered for fire monitoring and the number of outgoing commands for fire extinguishing. But in this article, we want to find the most optimal option for extinguishing the fire of public places such as the server room, which is one of the most used, and suggest it to you.

What is the proposed system and what are its characteristics?

Parameters such as cost, access to equipment, warranty, product support, equipment integrity, compatibility of fire alarm and fire extinguishing equipment with each other are all the main parameters for optimal selection of gas fire extinguishing system in every society. But in today’s Iranian society, which is affected by economic sanctions, parameters such as integrity, consistency and reasonable cost cannot be achieved, for example, the Fm200 fire extinguishing system, which must meet the standard of product integrity in its various equipment, such as hoses, solenoid valves, It does not matter if the activator or the activator is the gas outlet nozzles and most importantly the fire extinguishing gas, so the optimal suggestion is to use domestically produced standard fire extinguishing equipment that is of high efficiency and approved by competent bodies such as the fire department. Among the gas fire extinguishing equipment approved by Iran’s national firefighting and standards organization is the Aerocel dense gas fire extinguishing system produced by Hamiyar Energy Company. This product, which was produced for the first time in the world with a special and special formula with the attitude of solving the past problems of this product in the past decades, has special features that make it different from similar domestic and foreign products. Among these features are high fire extinguishing power, no residue, no flame formation and the presence of a cool body, resistant to high humidity and high expansion power in gas distribution, all of which are specific to Hamyar Energy Company’s products. By using Aerocel system, there is no need for piping, complex design and high costs of this design, heavy costs of service and maintenance of this equipment, without causing corrosion and damage to equipment and documents, as well as without reducing oxygen to complete fire extinguishing in a short time. And it arrived at a more affordable cost.

Conclusion:

As mentioned in this article, all the important parameters must be taken into account in order to achieve a suitable fire extinguishing system, and the practicality of project implementation is one of the most important points in this field, so you can use modern science and software. related to the experts designing the fire alarm and extinguishing systems of Hamiyar Energy Company and considering the limitations and parameters of the optimal selection, achieve a system of automatic fire alarm and extinguishing that will provide you with the highest efficiency in times of crisis with the lowest side costs and Get after the accident.

دیدگاه خود را با ما در میان بگذارید

AVG ratings 5 از 5
Vote count: 1 Vote

همیار انرژی در شبکه های اجتماعی

0912-8932367

مقالات بیشتر

Leave a Comment

Your email address will not be published. Required fields are marked *

دانلود محتوا

لطفا برای دریافت لینک دانلود اطلاعات خواسته شده را وارد نمایید
Scroll to Top
تماس با همیار انرژی

021-43000049